| Construction |
- Stable galvanized and painted steel cabinet with 1 mm sheet metal thickness for flexible adaptation of various locking systems up to anti-vandal versions. Housing connected by force with 4 compartments stacked on top of each other, prepared for connections with multiple cabinet columns in series. The housing is designed to accommodate cable ducts of different types. Base separately made of stainless steel for floor mounting with height adjustment.
|
| Surface |
- RAL 9010 pure white, RAL 1021 rapeseed yellow, RAL 9007 grey aluminum, RAL 7016 anthracite grey, RAL 5002 ultramarine, RAL 5012 light blue, RAL 6005 moss green RAL 7035 light grey, RAL 3000 fire red, RAL 2008 light orange, RAL 9006 white aluminum, RAL 3020 traffic red, RAL 5017 traffic blue, RAL 4010 telemagenta, RAL 4004 bordeaux violet, DB 703
|
| Dimensions |
- Niche size: approx. 440 x 400 x 450 mm (H x W x D)
- Clear opening: approx. 400 x 315/330 mm (H x W)
- Cabinet dimensions: approx. 1,850 x 400 x 520 mm (H x W x D)
- For outdoor use plus a solid side cladding of 30 mm thickness with width 460 mm
- Overall cabinet height: Straight 2,030 mm / with sloped roof 2050 mm, incl. plinth 420 mm for installation on the foundation (u. OKF) of bicycle parking facilities
|
| Doors |
- Doors made of double-walled steel, swing type, self-closing from 30°, operated without disturbing adjacent lockers. Alternatively available in HPL, wood, glass, and synthetic stone with basic locking techniques.
|
| Außenbereich |
- For installation outdoors with a fixed anti-vandalistic cladding of 30 mm thickness on the sides and a cover for the back wall made of 1 mm thick steel sheet, sloped roof design so that no standing water can accumulate; also available without slope upon request. Upper mounting angle for increased stability and further mountings available upon consultation.
|
| Versions |
- Standard labeling with 2 logos each as charging station, optionally large lettering
- Standard operating instructions on and in the cabinet
|
| Protection |
- Factory protected for direct connection and commissioning by your local qualified electrician.
- Compliant construction of such low-voltage systems according to the following EU directives and resulting national laws:
- Low Voltage Directive 2014/35/EU
- EMC Directive 2014/30/EU
- RoHS Directive 2011/65/EU
|
| DIN Standards |
- The harmonized standards derived from the guidelines have been implemented in the products. These include, among others, the standards:
- DIN VDE 0100-722 VDE 0100-722:2019-06, Installation of low voltage systems
- DIN EN IEC 61851-1 VDE 0122-1:2019-12, Conductive charging systems for electric vehicles
- Interior fittings: Power supply for outdoor areas per compartment with 1 splashproof socket, intermediate floors for separating compartments in height optional.
|
| Locking System |
- Cylinder lock with HS or letterbox: Door closed, key issuance e.g. against deposit required, administration required
- Deposit lock: Door unlocked, compartment always open
- PIN Code lock: Door closed, with fixed PIN and administration against deposit etc., administration possible
- PIN Code lock: Door unlocked, with free PIN choice by the user
- RFID (on request)*: Door closed, upon appropriate operation, administration must adhere to specification
- RFID (on request)*: Door unlocked, if no operating specification is adhered to
- Electric girocard*: Door closed, customer asked to always close the door, administration electrically released
- *For RFID and girocard variants, the use of an emergency opener for total failure – power failure etc. – is strongly recommended by the operator.
|
| Locking System Variants |
- Turn latch for padlock, cylinder lock with 2 keys each, deposit box choice of €1 or €2, PIN code (battery operated with possible battery check), RFID networked (only available upon request for industrial customers), money card for identification or with payment function
|